Data Center Infrastructure Design Webinar l IEEE LAU Student Branch

Knowledge Base2 minutes read

Shahir Shaban, an experienced professional in structured cabling and data centers, discusses the various types of data centers and their components, emphasizing the importance of DCIM and adherence to international standards for operational efficiency and reliability. The design and maintenance of data centers involve considerations such as cooling capacity, cleanliness, power systems, and efficiency benchmarks like PUE, with renewable energy sources as supplemental options to ensure uninterrupted operations and connectivity.

Insights

  • Different types of data centers, such as enterprise, managed services, collocation, cloud, and edge data centers, serve distinct purposes and clientele, with variations in ownership and management structures.
  • Tier levels categorize data centers based on redundancy and availability, with Tier 4 offering fault-tolerant design and 99.9995% availability, emphasizing the critical importance of reliability and operational continuity in data center infrastructure.

Get key ideas from YouTube videos. It’s free

Recent questions

  • What are the main components of a data center?

    IT infrastructure, power systems, cooling systems, and more.

  • What is Data Center Infrastructure Management (DCIM)?

    It is crucial for controlling and managing data center systems.

  • What are the different types of data centers?

    Enterprise, managed services, collocation, cloud, and edge data centers.

  • What are the international standards for data centers?

    ISO, ITU, IEEE, TIA, and Uptime Institute set standards.

  • How are data centers categorized based on redundancy?

    Tier levels categorize data centers based on redundancy.

Related videos

Summary

00:00

Data Center Infrastructure: Components, Management, Standards

  • Shahir Shaban, a computer and communications graduate, worked in the UAE for 14 years before relocating to Canada, specializing in structured cabling, including copper and fiber data communications, and data centers.
  • The presentation focuses on data center infrastructure, highlighting components beyond IT and data that keep data center equipment operational.
  • Data center types include enterprise, managed services, collocation, cloud, and edge data centers, each serving different purposes and clientele.
  • Enterprise data centers are privately owned and managed, while managed services data centers are operated by third parties for rental purposes.
  • Collocation data centers offer space rental within a facility, cloud data centers provide virtual asset rental, and edge data centers are placed close to applications for reduced latency and improved management.
  • Main data center components include IT infrastructure (racks, servers, connectivity), power systems (transformers, UPS, generators), and cooling systems (chillers, pumps).
  • Additional systems in a data center encompass physical equipment and solutions, security measures, safety protocols, and fire detection and suppression systems.
  • Data Center Infrastructure Management (DCIM) is crucial for overall control and management of data center systems and operations.
  • Data centers adhere to international standards set by organizations like ISO, ITU, IEEE, TIA, and Uptime Institute, focusing on reducing downtime and ensuring operational efficiency.
  • Tier levels categorize data centers based on redundancy in capacity components and distribution paths, with Tier 4 offering fault-tolerant design and 99.9995% availability, while Tier 3 provides concurrently maintainable systems with 99.982% availability, and Tier 2 offers redundant systems with 99.7% availability.

20:12

Understanding Data Center Tiers and Design Essentials

  • Tier 1 data centers lack redundancy, exemplified by the power path system.
  • In a Tier 1 setup, having only two UPS modules with a single distribution path signifies no redundancy.
  • Tier 2 introduces redundancy with two UPS modules, providing a backup in case of failure.
  • Tier 2's redundancy is represented by having three UPS modules, exceeding the requirement of two.
  • Tier 3 data centers offer concurrent maintenance with an active and alternative path for power distribution.
  • In Tier 3, having three UPS modules with two distribution paths ensures operational continuity during maintenance.
  • Tier 4 data centers are fault-tolerant, ensuring continuous operation even after component failures.
  • Tier 4 data centers feature redundant components and power sources, guaranteeing uninterrupted service.
  • Designing a data center involves understanding business needs, IT equipment requirements, and environmental considerations.
  • Compliance with standards, modularity, and cost-efficiency are key recommendations for data center design.

39:11

Efficient Cooling and Power Systems in Data Centers

  • Data centers can increase cooling capacity up to 20 kilowatts per rack to maximize space usage.
  • Different cooling methods like downflow and upflow can be utilized, with direct-to-chip cooling being the most efficient but complex and costly.
  • Maintaining a clean area in data centers is crucial to prevent dust from damaging sensitive equipment.
  • Pressure differentials are used to control airflow within data centers to keep dust out and maintain cleanliness.
  • Power systems in data centers require a utility power supply, a generator, and a UPS for backup during power interruptions.
  • UPS systems are essential for data centers, with a recommended backup time of 15 minutes to allow for generator activation.
  • Dynamic rotary UPS systems store power as mechanical energy and are connected to generators for uninterrupted power supply.
  • Power Usage Efficiency (PUE) is a benchmark for data centers, with lower values indicating more efficient power usage.
  • Data centers can utilize renewable energy sources like solar power, but reliability concerns make them secondary power sources.
  • Data centers store and manage internet data, making them essential for online operations and connectivity.
Channel avatarChannel avatarChannel avatarChannel avatarChannel avatar

Try it yourself — It’s free.